Solar Recycling Case Studies
Solar Recycling Case Studies
Real jobs from our records: what the client needed, what made it tricky, and how it turned out. We’ve withheld client names, but every figure comes from our Waste Transfer Notes, test records and project emails.
- 1,000 panels off a supermarket roof, more than three-quarters reused
- Five O&M sites cleared on the same day
- 29.4 tonnes of solar equipment across the jobs on this page
- 1,187 used panels functionally tested
The jobs on this page
1,000 panels off a supermarket roof, mostly reused
The client: an energy services contractor upgrading the solar array on a supermarket store roof in Greater Manchester. About 1,000 older 250W panels were coming off to make way for the new system.
The challenge: the job came to us only days before the panels came off, after the contractor had first planned a different disposal route. Collections had to fit around the contractor’s working hours on site and change when their operatives weren’t there. Loading was by a 17-metre telehandler. Some panels were soiled after years at a low roof pitch.
What we did: the first collection ran two days after the job was confirmed: 15 pallets, panels stacked 27 to a pallet. We moved later loads around the contractor’s programme and cleared the site in three collections over eight days. All loads went on one Waste Transfer Note, which the project manager signed online.
The result: 12.15 tonnes cleared. More than three-quarters of the panels passed testing and went for reuse instead of recycling. When the contractor’s client later asked for evidence of where the panels went, for its sustainability reporting, the paperwork was ready to send.
- 01Client typeEnergy services contractor
- 02SiteSupermarket store roof, Greater Manchester
- 03WhyUpgrade: old 250W panels replaced
- 04VolumeAbout 1,000 panels, 12.15 tonnes, 3 collections
- 05OutcomeMore than 75% passed testing and were reused
- 06What happened nextThe same contractor booked us for its next project: about 1,500 panels at a hospital in Norfolk
“Thanks for all of the effort you put into this, the service was flawless.”
Project Manager, energy services contractor (case study 01)
Five solar sites cleared on the same day
The client: a national solar operations and maintenance (O&M) provider with damaged and faulty modules sitting at sites across southern and eastern England.
The challenge: small quantities spread across distant sites. Some sites had as little as 18 kg of waste, the largest 361 kg. Loads that small can be hard to get collected, and each site’s owner needs its own paperwork.
What we did: we booked a separate collection for each site, in Devon, Dorset, Somerset, Hampshire and Cambridgeshire, all on the same day. Every site got its own Waste Transfer Note.
The result: all five sites cleared in one day. The modules had cracks, faults or other damage, so all of them went to approved recycling. The O&M provider can give each asset owner paperwork for its own site.
- 01Client typeSolar O&M provider
- 02Sites5, cleared on the same day
- 03WasteDamaged and faulty PV modules
- 04VolumeAbout 0.5 tonnes in total, 18 kg to 361 kg per site
- 05OutcomeAll recycled through approved facilities
- 06PaperworkOne Waste Transfer Note per site
Other solar collections
How many used panels passed testing?
These are four batches of used panels functionally tested with an I-V curve tracer, with the readings corrected for light conditions. Panels that pass can be certified for reuse rather than recycled. Readings marked invalid couldn’t be graded reliably, so those panels weren’t counted as passes or fails.
| Panel type | Tested | Passed | Failed | Invalid reading | Pass rate (valid readings) |
|---|---|---|---|---|---|
| 60-cell polycrystalline (ET Solar) | 925 | 816 | 14 | 95 | 98% |
| Older 160W modules (Sharp) | 102 | 93 | 0 | 9 | 100% |
| Modern half-cut mono (LONGi) | 82 | 77 | 1 | 4 | 99% |
| Thin-film amorphous (Uni-Solar) | 78 | 69 | 2 | 7 | 97% |
Failures were mostly low open-circuit voltage or suspected bypass diode faults. Source: Olital test records, 2026.
Frequently asked questions
Have a job like one of these?
Send us the quantity, panel type, location and deadline. We’ll come back with a written quote.
0330 223 7062 Get My Quote →